Single-pole C-curve MCBs compared: ABB S200 vs Schneider Acti9 iC60N vs Hager
One row per rating, one order code per range, with the breaking capacity each manufacturer states for it. The C curve is the general-purpose characteristic for mixed resistive and inductive loads; each range also offers B and D curves.
| Rated current (1P, C curve) | ABB S200 (S201)on RMS-ABB.Africa — priced herebreaking capacity from the range line of the ABB price list | Schneider Electric Acti9 iC60Non RMS-SE.AfricaIcn (IEC 60898-1) and Icu (IEC 60947-2) as stated in the product title | Hager MA / HLF (ElectroMechanica)on RMS-EM.Africabreaking capacity as stated in the product title; the series with the widest 1P C-curve coverage fills each row, the others fill its gaps |
|---|---|---|---|
| 0.5 A | No product at this rating | No product at this rating | MA100Z
|
| 1 A | No product at this rating | A9F74101
| MA101Z
|
| 2 A | 2CDS251001R0024
R152.60 View & add 2CDS251001R0024 — 2 A | A9F74102
| MA102Z — RMS-EM.Africa
|
| 3 A | No product at this rating | A9F74103
| MA103Z
|
| 4 A | No product at this rating | A9F74104
| No product at this rating |
| 6 A | 2CDS251001R0064
R112.58 View & add 2CDS251001R0064 — 6 A | A9F77106
| MA106Z — RMS-EM.Africa
|
| 10 A | 2CDS251001R0104
R112.58 View & add 2CDS251001R0104 — 10 A | A9F77110
| MA110Z — RMS-EM.Africa
|
| 16 A | 2CDS251001R0164
R112.58 View & add 2CDS251001R0164 — 16 A | A9F77116
| MA116Z — RMS-EM.Africa
|
| 20 A | 2CDS251001R0204
R112.58 View & add 2CDS251001R0204 — 20 A | A9F77120
| MA120Z — RMS-EM.Africa
|
| 25 A | 2CDS251001R0254
R116.33 View & add 2CDS251001R0254 — 25 A | A9F77125
| MA125Z — RMS-EM.Africa
|
| 32 A | 2CDS251001R0324
R116.33 View & add 2CDS251001R0324 — 32 A | A9F74132
| MA132Z — RMS-EM.Africa
|
| 40 A | 2CDS251001R0404
R116.33 View & add 2CDS251001R0404 — 40 A | A9F77140
| MA140Z — RMS-EM.Africa
|
| 50 A | 2CDS251001R0504
R131.34 View & add 2CDS251001R0504 — 50 A | A9F77150
| MA150Z — RMS-EM.Africa
|
| 63 A | 2CDS251001R0634
R136.35 View & add 2CDS251001R0634 — 63 A | A9F77163
| MA163Z — RMS-EM.Africa
|
| 80 A | 2CDS251001R0804
R415.39 View & add 2CDS251001R0804 — 80 A | No product at this rating | HLF180S — RMS-EM.Africa
|
| 100 A | 2CDS251001R0824
R415.39 View & add 2CDS251001R0824 — 100 A | No product at this rating | HLF190S — RMS-EM.Africa
|
| 125 A | No product at this rating | No product at this rating | HLF199S — RMS-EM.Africa
|